GENERAL CHEM CORP (PROD PREV OWNED BY ALLIED CHEM) -- HYDROCHLORIC ACID -- 6810-00N011553
=====================  Product Identification  =====================

Product ID:HYDROCHLORIC ACID
MSDS Date:09/01/1986
FSC:6810
NIIN:00N011553
=== Responsible Party ===
Company Name:GENERAL CHEM CORP (PROD PREV OWNED BY ALLIED CHEM)
Address:90 E HALSEY
Box:395
City:PARSIPPANY
State:NY
ZIP:07054
Country:US
Info Phone Num:800-631-8050
Emergency Phone Num:800-631-8050
CAGE:HO700
=== Contractor Identification ===
Company Name:GENERAL CHEM CORP (PROD PREV OWNED BY ALLIED CHEM)
Address:90 E HALSEY
Box:395
City:PARSIPPANY
State:NY
ZIP:07054
Country:US
Phone:800-631-8050
CAGE:HO700
Company Name:GENERAL CHEMICAL CORPORATION
Address:90 EAST HALSEY ROAD
Box:City:PARSIPPANY
State:NJ
ZIP:07054
Country:US
Phone:973-515-1840
CAGE:0AU44

=============  Composition/Information on Ingredients  =============

Ingred Name:HYDROGEN CHLORIDE  (HYDROCHLORIC ACID)  (SARA III)
CAS:7647-01-0
RTECS #:MW4025000
Other REC Limits:N/K 
OSHA PEL:C 5 PPM
ACGIH TLV:C 5 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 RABBIT ORAL 900 MG/KG. (SEE SUPP)
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:CAN COMPLETELY DESTROY MUCOUS
    MEMBRANES DURING INHALATION.INGESTION:SEVERE BURNING OF
    MOUTH,PHARYNX,ABDOMEN.ASPHYXIA MAY OCCUR FROM EDEMA OF
    GLOTTIS.DERMATITIS & PHOTOSENSITIZATION.CONJUNCTIVAL EDEMA	&
    CORNEAL DESTRUCTION MAY CAUSE BLINDNESS.POISON-INGESTION MAY BE
    FATAL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES:CONJUNC EDEMA & CORNEAL DESTRUCTION POSS
    CAUSING BLINDNESS.PAIN,TEARING,PHOTOPHOBIA.VAP IS IRRIT.SKIN:SEV
    PAIN,BROWNISH/YELLOW STAINS.PENETRATES
    SKIN.DERM,PHOTOSENSITIZATION.INGEST:SEV BURNS OF M
    OUTH,PHARYNX,ABDOMEN,VOMIT,WEAKNESS,ASPHYXIA.POSS
    FATAL.INHAL:DESTRUCT OF MUC MEMB,CHOKING,COUGH,HDCH,DIZZ.PULM
    EDEMA.
Medical Cond Aggravated by Exposure:N/K 

=======================  First Aid Measures  =======================

First Aid:EYES:IMMED FLUSH W/ H*2O 20-30 MIN,HOLDING LIDS OPEN.CALL
    MD.USE NO CHEM ANTIDOTE.SKIN:IMMED FLUSH W/ H*2O FOR AT LEAST 15
    MIN.REMOVE CONTAM CLTHG.USE NO CHEM ANTIDOTES.CALL MD.PH >3 PROMPT
    WASHING NE C.INGEST:IMMED DRINK LRG AMT H*2O/MILK TO DILUTE
    100X;REPEAT IF VOMIT.DO NOT INDUCE VOMIT.CALL MD.INH:IMMED MOVE TO
    FRESH AIR.DFCLT BRTHG-GIVE O*2.BRTHG STOPS-GIVE ARTF RESP.SYMP
    PERSIST-GET MED HELP.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:IF INVOLVED IN A FIRE,USE WATER.ALSO MAY NEUTRALIZE
    WITH ALKALIS SUCH AS SODA ASH OR LIME.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .USE WATER SPRAY TO COOL FIRE-EXPOSED
    CONTAINERS.DO NOT SPLASH THIS MATL ONTO OTHER PERSONNEL.
Unusual Fire/Explosion Hazard:CO*2 POSS DURING NEUT.CONT W/ METALS MAY
    GENERATE HYDROGEN GAS-A SERIOUS FIRE/EXPLO HAZARD.HCL EVOLUTION
    INCR BY HEAT/CONT W/ WATER-REACTIVE MATLS.TOXIC GASES.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EYE-PROTECTED PERSONNEL SHOULD REMOVE SPILLS
    IMMEDIATELY BY FLUSHING AWAY WITH LOTS OF WATER.FULLY PROTECTED
    (INCLUDING FACESHLD) PERS MAY CAREFULLY NEUTRALIZE W/ ALKALIS SUCH
    AS SODA ASH OR LIME.USE  AMPLE VENT WHEN NEUTRALIZING TO ELIM CO*2
    FORMED.
Neutralizing Agent:ALKALIS SUCH AS SODA ASH OR LIME.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID CONT W/ SKIN/EYES/CLTHG/INHAL OF
    VAP.KEEP AWAY FROM METALS,INCOMPATIBLE CHEMS.STORE IN DRY,WELL-VENT
    AREA,AWAY FROM HEAT,FLAM MATLS,OUT OF SUN.
Other Precautions:PROT FROM PHYS DMG & KEEP CONTR CLSD & UPRIGHT.CORR
    MATL.DANGER CAUSES BURNS.POSS FATAL IF INGEST.POISON.REC MED
    SURVEILLANCE & PERS EDUCATION.NO FLAMES,SPARKS,SMOKING IN STORE
    AREA.VENT PACKAGING,UNL OADING,OPEN PROCESSING AREAS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
    CONCENTRATION BELOW TLV .
Protective Gloves:ACID-RESISTANT GAUNTLET GLOVES.
Eye Protection:CHEM WORK GOGG,WITH FACESHIELD .
Other Protective Equipment:ACID-RESIST (NEOPRENE OR NITRILE-BUTADIENE
    RUB) APRON,TROUSERS & JACKET,BOOTS.EYEWASH & QUICK-DRENCH.
Work Hygienic Practices:NO CONT LENSES.IMMED WASH CONTAM IMPERVIOUS
    ITEMS.IMMED REMOVE CONTAM NON-IMPERVIOUS ITEMS.
Supplemental Safety and Health
VP:30 MMHG @ 25C,77F.VAP DENS:EST 1.3
    (AIR=1).PH:1N-0.1,0.1N-1.1,0.02N-2.02,0.002N-3.02.MATLS TO
    AVOID:H*2O-REACTIVE MATLS (CONC H*2SO*4),OLEUM,ACETIC
    ANHYDRIDE.CARBONATES,CYANIDES,SULFIDES LIBERATE T OX GASES.RTS OF
    ENTRY:ALL .LD50-LC50 MIX:LC50 RAT INHAL 3124 PPM/1 HR.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:51C,122F
Melt/Freeze Pt:M.P/F.P Text:-74C,-101F
Decomp Temp:Decomp Text:N/K 
Vapor Pres:SEE SUPP
Vapor Density:SEE SUPP
Spec Gravity:1.19 (WATER=1)
pH:SUP DA
Evaporation Rate & Reference:>1 (ETHER=1)
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID WITH PUNGENT ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
METALS,ALKALIS,METALLIC OXIDES,AMINES,STRONG OXIDANTS (FL),VINYL
    ACETATE,PROPIOLACETONE (BETA),PROPYLENE OXIDE (SUP DA)
Stability Condition to Avoid:N/K 
Hazardous Decomposition Products:HCL EVOLUTION ACCELERATED BY HEAT OR
    CONT W/ WATER-REACTIVE MATLS (CONCENTRATED H*2SO*4).CO*2 DURING
    NEUT.TOX GASES.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
    FEDERAL,STATE AND LOCAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.