COLONIAL CHEMICAL COMPANY -- BATTERY FLUID,ACID -- 6140-01-126-3995
===================== Product Identification ===================== Product ID:BATTERY FLUID,ACID MSDS Date:01/01/1987 FSC:6140 NIIN:01-126-3995 === Responsible Party === Company Name:COLONIAL CHEMICAL COMPANY Emergency Phone Num:(609)268-0278 CAGE:2L633 === Contractor Identification === Company Name:COLONIAL CHEMICAL CO Address:R D NO 3 TABERNACLE CARRANZA RD Box:City:VINCETOWN State:NJ ZIP:08088-9804 Country:US Phone:609-268-1200 CAGE:2L633 ============= Composition/Information on Ingredients ============= Ingred Name:SULFURIC ACID (SARA III) CAS:7664-93-9 RTECS #:WS5600000 Fraction by Wt: 29%. OSHA PEL:1 MG/M3 ACGIH TLV:1 MG/M3; 9192 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:WATER,CAS#7732-18-5 CAS:7732-18-5 RTECS #:ZC0110000 ===================== Hazards Identification ===================== Effects of Overexposure:FUMES NOT PRESENT AT AMBIEN TEMPS.LIQUID CAUSES SEVERE BURNS OF SKIN & EYES. ======================= First Aid Measures ======================= First Aid:EYE:FLUSH W/WTR 15MIN HOLDING EYELID OPEN.SEE DR;SKIN:BLOT IF PRACTICAL,FLUSH W/LG AMTS OF WTR.REMOVE CLOTHNG IF CONTAMINATED,SEE DOCTOR/ ===================== Fire Fighting Measures ===================== Flash Point:NONE Extinguishing Media:EXTINGUISH WITH AGENT SUITABLE FOR SURROUNDING FIRE Fire Fighting Procedures:COOL OUTSIDE CONT.W/WTR.DO NOT LET WTR TO CONTACT ACID. Unusual Fire/Explosion Hazard:MAY CAUSE FIRE IN CONTACT W/ORG.MTLS.WILL ATTACK SOME METLS&RELEASE FLAMM&EXPL.H*2 GAS. ================== Accidental Release Measures ================== Spill Release Procedures:ZONE OFF CONTAM.AREA.NEUTRALIZED W/SODA ASH,CAUSTIC SODA,LIME,AMMONIA OR OTHER ALK.AGTS.FLUSH AREA W/LG.AMTS OF WTR FROM SAFE DISTANCE. ====================== Handling and Storage ====================== Handling and Storage Precautions:STOR.ONLY IN APPVD TYPE CONT.AVOID ROUGH HANDLING OF DRUMS.VENT DRUMS WKLY TO RELEASE PRESS.ALWAYS HAVE WTR SAFETY SHOWERS & EYEWASH STATIONS. Other Precautions:NO SMOKING REGULATION MUST BE ENFORCED BECAUSE OF PRESENCE OF HYDROGEN GAS.SEE MCA CHEMICAL SAFETY DATA SHEET SD-20 SULFURIC ACID. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:PROPER ACID CANNISTER TYPE-FULL FACE PIECE(SEE MCA DATA SHEET SD-20) Ventilation:LOCAL EXH.& MECH.GNL TO MEET TLV.-USE CORR.RESIST.MATERIAL. Protective Gloves:RUBBER Eye Protection:GOGGLES/FACE SHIELD Other Protective Equipment:HARD/SOFT HATS,RUBBER SFTY SHOES W/STEEL TOE,RUBBER APRON. Supplemental Safety and Health MSDS DATED 09-16-85/ ================== Physical/Chemical Properties ================== HCC:C1 Boiling Pt:B.P. Text:225F,107C Vapor Pres:<1. Spec Gravity:1.21 Solubility in Water:COMPLETE Appearance and Odor:CLEAR,COLORLESS,SOMETIMES CLOUDY,USUALLY ODORLESS. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES COMBUSTIBLE MTLS&ORGANIC MTLS. Stability Condition to Avoid:ADDITION OF WATER. Hazardous Decomposition Products:NONE ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF IAW ALL GOVERNMENTAL REGS.-SEE MCA MANUAL,SHEET W-3 ON NEUTRALIZATION OF ACID & ALKALINE PLT EFFLUENTS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.